Capacitive Liquid Level Sensor
DSW-3 series (non-contact liquid level module)Detailed Description:
WORKING PRINCIPLE:
The DSW-1 and DSW-2 series of capacitive liquid sensors utilize the principle of capacitance. When the liquid height reaches the contact surface of the sensor, it will cause a change in capacitance value. The controller compares the change amount and converts it into a high and low level or voltage value output signal. The external control board can determine the corresponding liquid level height by detecting the high and low level signals or different voltage values. The DSW-3 series non-contact liquid level module also integrates signal detection functions of optocoupler liquid level sensors and liquid level switches. The signals are processed by the module and then output together, reducing the number of connecting wires.
TECHNICAL REQUIREMENT:
Product | Structure | Operating Voltage | Output Current | Output Signal | Accuracy | Response Time | Operating Temp. | Storage Temp. | Applicable Medium | Remarks |
DSW-1/DSW-3 | Non-contact | DC 5±0.3V | <15mA | High/low level signal | Return difference between on and off is ≤3mm | <100ms | -5~80℃ | -20~85℃ | Liquids with capacitance value such as water and ethanol | not for metal containers, container thickness≤10mm |
DSW-2 | Immersion Single Point Control | DC 5±0.3V | <15mA | High/low level signal | <100ms | -5~80℃ | -20~85℃ | Can be applied to some viscous liquids, such as oil | ||
DSW-2 | Immersion multi-point control | DC 5±0.3V | <15mA | Voltage value | <500ms | -20~150℃ | -20~85℃ | Range can be customized |
If you want to know more, please contact us 400-930-4382
contact us© 2020 Chuandong magnetic. All rights reserved 粤ICP备17110255号